- PS-5700T Performance
- PS-5700T iCore7
- 15"

Documentation

Support

Quick Information

Software

Certifications
1When installed, an optional disk adapter unit (PFXZPBADHDD2) that is separately sold is required.
International Safety Standards | ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Rated Input Voltage | DC Power Model: 24 Vdc ±20 %
When using AC power supply unit: 100 to 240 Vac *2 |
Power Consumption | 25.9 W (Max. 44.9 W)
|
In-Rush Current | 8.9 A
|
Surrounding Air Temperature | When using SSD / CFast running: 0 to 55 ℃ [32 to 131 ℉]
When using HDD running: 0 to 45 ℃ [32 to 113 ℉] When using mPCI x 2 + Display module : 0 to 45 ℃ [32 to 113 ℉]] When using PCI/PCIe : 0 to 45 ℃ [32 to 113 ℉]] |
Storage Temperature | -30 to 70 ℃ [-22 to 158 ℉]
|
Ambient Humidity | 10 to 95 % RH (Wet bulb temperature: 40 ℃ [104 ℉] max. - no condensation)
|
Storage Humidity | 10 to 95 % RH (Wet bulb temperature: 40 ℃ [104 ℉] max. - no condensation)
|
Pollution Degree | For use in Pollution Degree 2 environment
|
Air Pressure (altitude range) | 2,000 m [6,560 ft] max.
|
Vibration Resistance | Operation for products with SSD / CF card storage device: 5 to 500 Hz: 2 Grms
Operation for products with HDD storage device: 5 to 500 Hz: 1 Grms |
Concussion Resistance | IEC 60068-2-27 Ea test
|
Electromagnetic Compatibility (EMC) | Immunity to High Frequency Interference
Electromagnetic Emissions Class A |
Structure | IP66 (front side of display)
|
Installation Configuration | Panel mounting / VESA mounting*3
|
Cooling Method | Passive heat sink*4
|
Weight Approx. | 0 slot: 7.3 kg (16 lbs.)
2 slot: 8.1 kg (17.8 lbs.) |
External Dimensions | 0 slot: W390.7 x H290.0 x D93.2 mm [W15.38 x H11.42 x D3.67 in.]
2 slot: W390.7 x H290.0 x D131.2 mm [W15.38 x H11.42 x D5.16 in.] |
Panel Cut Dimensions | W383.5 x H282.5 mm [W15.09 x H11.12 in.]
|
2For use at 100 to 240 Vac, an optional AC/DC power adapter (PFXZPSPUAC3) that is separately sold is required.
3For VESA mounting, an optional VESA mounting kit (0 slot: PFXZPBADVS02, 2 slot: PFXZPBADVS22) that is separately sold is required.
4The operating temperature is limited to 45 ℃ and the cooling FAN is required for PCI/PCIE cards installed on board with power consumption from 3 W to 6 W maximum for two cards or 10 W maximum for one card.
A | B | C | R |
---|---|---|---|
383.5 ±0.7 mm (15.09 ±0.03 in.) |
282.5 ±0.4 mm (11.12 ±0.02 in.) |
2 to 6 mm (0.08 to 0.23 in.) |
5 mm (0.20 in.) |
Copyright (c) 1996-2019 Schneider Electric Japan Holdings Ltd. All Rights Reserved.