Site Map Product Pricing  
Pro-face America Home



 
Our Products About Us News & Annoucements Resource Library Customer Support Distributor Locator Partners Login  
   Product Directory | HMI Software | Operator Interfaces | Operator Interfaces Plus Control | Industrial Computers | Flat Panel Monitors | Smart Relays | Discontinued Products | Refurbished and Opened Box Store
PRO-IO: Smart I/O Modules:
New Product

Pro-IO 2: Smart I/O Modules for Logic Relay

Logic Relay Programming - easy to program, low cost modules




DOCUMENTATION
Pro-IO 2: Smart Logic Relay Modules

Model Line-up


- With Display


Model Input Output
Input points
(Analog Input points)
Input Normal Input Analog
(Both Analog and Digital)
Output points Output 8A Output 5A
DR2-B201BD 12 (6) I1 to I6 IB to IG 8 Q1 to Q8 -
DR3-B261BD 16 (6) I1 to IA IB to IG 10 Q1 to Q8 Q9,QA
DR2-B201FU 12 I1 to IC - 8 Q1 to Q8 -
DR3-B261FU 16 I1 to IG - 10 Q1 to Q8 Q9,QA


Model Input Output
Input points
(Analog Input points)
Input Normal Input Analog
(Both Analog and Digital)
Output points Output 8A Output 5A
DR2-B121BD 8 (4) I1 to I4 IB to IE 4 Q1 to Q4 -
DR3-B101BD 6 (4) I1 to I2 IB to IE 4 Q1 to Q4 -
DR2-B121FU 8 I1 to I8 - 4 Q1 to Q4 -
DR3-B101FU 6 I1 to I6 - 4 Q1 to Q4 -


- Without Display


Model Input Output
Input points
(Analog Input points)
Input Normal Input Analog
(Both Analog and Digital)
Output points Output 8A Output 5A
DR2-D201BD 12 (2) I1 to IA IB , IC 8 Q1 to Q8 -
DR2-D201FU 12 I1 to IC - 8 Q1 to Q8 -


Model Input Output
Input points
(Analog Input points)
Input Normal Input Analog
(Both Analog and Digital)
Output points Output 8A Output 5A
DR2-D101BD 6 I1 to I6 - 4 Q1 to Q4 -
DR2-D101FU 6 I1 to I6 - 4 Q1 to Q4 -


- Extension Unit


Model Input Output
Input points Input Normal Output points Output 8A Output 5A
DR3-XT61BD 4 IH,IJ,IK,IL 2 QB,QC -
DR3-XT141BD 8 IH,IJ,IK,IL,IN,IP,IQ,IR 6 QB to QE QF,QG
DR3-XT61FU 4 IH,IJ,IK,IL 2 QB,QC -
DR3-XT141FU 8 IH,IJ,IK,IL,IN,IP,IQ,IR 6 QB to QE QF,QG


- Application Software and Options

Name Model Description
PRO-iO2 Editor DR2-SFT01 Logic program development editor.
PRO-iO2 Data Transfer Cable DR2-CBL01 Connects the PRO-iO2 module to a PC to transfer logic programs.
PRO-iO2 Memory Pack DR2-MEM01 Used with DR*-B***** models to backup (save) logic programs.
Can copy logic programs to other DR*-B*****-type PRO-iO2 modules.


- PRO-iO (Old Model) and PRO-iO2's point of difference

Hardware 1.Old transfer cable cannot be used because connector shape has changed.
2.Old memory pack cannot be used because the connector shape is different.
3.Switch arrangement on the unit is different.
4.Terminal numbers changed because the number of analog input points for DC type increased.
5.View mode (VISU menu) in the display setting of the unit eliminated.
6.Backup time is expanded from 150 hours to 10 years.
7.Back light is added.
Software 1.The number of lines for program creation increased from 80 to 120 lines.
2.The number of internal coils increased from 15 to 28.
3.Backlight Control command added.
4.High-speed counter input (Max=1kHz) added.
5.PRO-iO2 editor cannot edit and transfer a program to PRO-iO (old model).

FEATURES

Relay Sequence Function

Basic ON/OFF control of a lamp, pump, etc. after receiving an input (a contact, b contact) such as a button or switch, Complex input conditions can also be made combining AND circuits, OR circuits, etc.

Counter Function

With this function an incoming signal is counted and made a pre-set value.

Example: On a product manufacturing line defective products can be detected and counted by a sensor.

Analog (certain models only)

This function inputs the analog signals of two points, temperature, pressure, etc., and outputs a result of the comparison of the two points and a set value.

Example: If temperatures rises too high in a greenhouse, a window will be opened automatically.

Timer Function

After receiving an incoming signal, unit waits a pre-set amount of time, then sends output.

Example: A washing machine switch is pushed, washing is started, and it stopped after 40 seconds.

Calender Function

This output function allows scheduling of regular events, such as weekly or daily.

Example: Equipment can be prepared for operation, such as having pre-heating every day at 6:00am.

HOW TO ORDER

Visit the online Product Pricing at Xycom.com for order numbers and pricing.
 

 

Pro-face     750 North Maple Road     Saline, MI 48176-1292     Phone: 1-800-289-9266     Email: customercare@profaceamerica.com
Privacy Policy | Terms of Use
© Copyright 2004-2008. Pro-face. All rights reserved.
We are interested in hearing from you: Tell us what you think.